| SPECIFICATIONS |
| MODEL |
6303 |
6306 |
6309 |
6315 |
6330 |
6360 |
6390 |
63120 |
| INPUT |
| Phase |
1ø |
3ø |
| Voltage |
230Vac±15% |
220/380Vac±10% |
| Frequency |
47-63Hz |
| OUTPUT |
| Max. Power |
Single-Phase |
1KVA |
2KVA |
3KVA |
5KVA |
10KVA |
20KVA |
30KVA |
40KVA |
| Total Power |
3KVA |
6KVA |
9KVA |
15KVA |
30KVA |
60KVA |
90KVA |
120KVA |
Max. Current (r.m.s)
, Single-Phase*1 |
0-150V |
8.4A |
16.8A |
25.2A |
42.0A |
84.0A |
168.0A |
252.0A |
336.0A |
| 0-300V |
4.2A |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
Max. Current (r.m.s), Single-Phase
(Option 0-600V)*2 |
0-300V |
4.2A |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
| 0-600V |
2.1A |
4.2A |
6.3A |
10.5A |
21.0A |
42.0A |
63.0A |
84.0A |
| Phase |
3ø/4W |
| Total Harmonic Distortion (T.H.D) |
< 1% at 47-63Hz (Resistive Load) |
| Crest Factor |
>3 |
| Line Regulation |
± 0.1V |
| Load Regulation |
L - N : ± (0.5% of output +0.5V) / L - L : ± (1% of output +1V) at Resistive Load |
| Deviation of phase angle |
120° ? ±1° at Load Balance, 120° <= ±2.5° at 100% Load Unblance |
| Response Time |
< 2 msec |
| SETTINGS |
| Voltage |
Range |
0-150V/0-300V Selectable or 0-300V/0-600V Selectable(Option 0-600V) |
| Resolution |
0.1V |
| Accuracy |
±(1% of setting + 2counts) |
| Frequency |
Range |
47.0-63.0Hz Full Range Adjust |
| Resolution |
0.1Hz |
| Accuracy |
±0.02% of setting |
| MEASUREMENT |
| Voltage |
L - N Range |
0.0-300.0V / 0.0-600.0V(Option 0-600V) |
| L - L Range |
0.0-520.0V / 0.0-1040V(Option 0-600V) |
| Resolution |
0.1V / 0.2V |
| Accuracy |
± (1% of reading + 2counts) |
| Frequency |
Range |
47.0-63.0Hz |
| Resolution |
0.1Hz |
| Accuracy |
±0.1Hz |
| Current (r.m.s) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
| H |
3.00-35.00A |
30.00-350.0A |
| Resolution |
L |
0.001A |
0.01A |
| H |
0.01A |
0.1A |
| Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
| H |
± (1% of reading +1count) |
± (1% of reading +1count) |
Current (r.m.s)
(Option 0-600V) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
| H |
3.00-35.00A |
30.00-350.0A |
| Resolution |
L |
0.001A |
0.01A |
| H |
0.01A |
0.1A |
| Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
| H |
± (1% of reading +1count) |
± (1% of reading +1count) |
| Power |
Range |
L |
0.0-350.0W |
0.000-3.500KW |
| H |
300-4000W |
3.00-40.00KW |
| Resolution |
L |
0.1W |
0.001KW |
| H |
1W |
0.01KW |
| Accuracy |
L |
± (1.5% of reading +5counts) |
| H |
± (1.5% of reading +1count) |
| Power Factor |
Range |
0.000-1.000 |
| Resolution |
0.001 |
| Accuracy |
W / V x A , Calculated and displayed to three significant digits |
| GENERAL |
| PLC Remote |
I/P:ON/OFF, P1, P2, P3, O/P:Processing |
| Memory |
8 Memoies, 5steps per memory for Voltage, Frequency, Test Time, Delay time and Current, Power, Power Factor Hi, Lo Limit setting. |
| Timer |
0=Continuous, 1-9999 (Unit: sec, minute, hour selectable) |
| Auto Loop Cycle |
0=Continuous, OFF=Loop Once, 2~9999 (Unit:×1, ×10, ×100) |
| Auto Voltage Adjust |
Enable it for improve voltage regulation within ±0.1V |
| Efficiency |
≧80%(at Full Load ) |
≧85%(at Full Load ) |
| Protection |
Over Load , Short Circuit , Over Temperature |
| Calibration |
Front Panel Calibration |
| Interface (Option) |
GPIB/RS232 |
| Environment |
0-40℃/20-80%RH |
| Dimension(W×H×D) mm |
430×622×650 |
430×622×650 |
430×756×650 |
430×756×650 |
600×845×900 |
800×1245×900 |
1200×1635×900 |
1200×1635×900 |
| Dimension with Caster(W×H×D) mm |
430×729×650 |
430×729×650 |
430×863×650 |
430×863×650 |
600×952×900 |
800×1390×900 |
1200×1805×900 |
1200×1805×900 |
| Dimension (W×H×D) mm (PFC) |
430×756×650 |
430×756×650 |
600×711×900 |
600×711×900 |
600×845×900 |
800×1245×900 |
1200×1635×900 |
1200×1635×900 |
| Dimension with Caster (W×H×D) mm (PFC) |
430×863×650 |
430×863×650 |
600×818×900 |
600×818×900 |
600×952×900 |
800×1390×900 |
1200×1805×900 |
1200×1805×900 |
| Net Weight |
130Kg |
145Kg |
171Kg |
207Kg |
366Kg |
487Kg |
820Kg |
1000Kg |
| Net Weight (PFC) |
167Kg |
195Kg |
248Kg |
309Kg |
530Kg |
760Kg |
1200Kg |
1250Kg |