6900 Series Simplify AC Power Source
Model
6905
6910
6920
6940
MODEL
6905
6910
6920
6940
INPUT
Phase
1 phase
Voltage
110 / 220Vac±10%
220Vac±10%
Frequency
50 / 60 Hz
AC OUTPUT
Power rating
500VA
1KVA
2KVA
4KVA
Max. Current (r.m.s)
0-150V
4.6A at 110V
9.2A at 110V
18.4A at 110V
36.8A at 110V
0-300V
2.3A at 220V
4.6A at 220V
9.2A at 220V
18.4A at 220V
Phase
1 phase / 2W
Total Harmonic Distortion (T.H.D)
< 0.5% 40 - 100Hz , <1% at 101-450Hz (Resistive Load)
Crest Factor
≧3
Load Regulation
± (0.5% of output +0.5V) at Resistive Load
Response Time
< 400usec
SETTINGS
Voltage
Range
0-150V/0-300V Selectable
Resolution
0.1V
Accuracy
±(1% of setting + 2counts)
Frequency
Range
40-450Hz Full Range Adjust
Resolution
0.1Hz at 40 - 99.9Hz , 1Hz at 100-450Hz
Accuracy
±0.03% of setting
DC OUTPUT (Option)
Max. Power
250W
500W
1000W
2000W
Max. Current
0-200V
2.3A
4.6A
9.2A
18.4A
0-400V
1.1A
2.3A
4.6A
9.2A
SETTINGS
Voltage
Range
0-200V / 0-400V Selectable
Resolution
0.1V
Accuracy
±(1% of setting + 2counts)
Ripple and Noise (RMS)
Range : 0-200V <250mV;
Range : 0-400V <400mV
Range : 0~200V <350mV;
Range : 0~400V <550mV
Ripple and Noise (p-p)
<2Vp-p
<3.0Vp-p
MEASUREMENT
Voltage (AC & DC)
Range
0.0-400.0V
Resolution
0.1V
Accuracy
± (1% of reading + 2counts)
Frequency
Range
0.0-500.0Hz
Resolution
0.1Hz
Accuracy
±0.1Hz
Current (AC & DC)
Range
0.00 - 54.00A
Resolution
0.01A
Accuracy
± (1% of reading +5counts)
Power
Range
0 -4000W
Resolution
1W
Accuracy
± (2% of reading +2counts)
Power Factor
Range
0.000-1.000
Resolution
0.001
Accuracy
W / VA ,Calculated and displayed to three significant digits
Opt.628 High Measurement Resolution (For 6905, 6910 & 6920)
AC OUTPUT
Current
Range
L
0.000A - 0.600A
0.000A - 1.200A
0.000A - 2.400A
-
H
0.50A - 6.00A
1.00A - 13.00A
2.00A - 27.00A
-
Resolution
L
0.001A
-
H
0.01A
-
Accuracy
± (1% of reading +5counts)
-
Power
Range
L
0.0W - 60.0W
0.0W - 120.0W
0.0W - 240.0W
-
H
50W - 500W
100W - 1000W
200W - 2000W
-
Resolution
L
0.1W
-
H
1W
-
Accuracy
± (2% of reading +5counts)
-
DC OUTPUT(Option)
Current
Range
L
0.010A - 0.600A
0.010A - 1.200A
0.0010A - 2.400A
-
H
0.50A - 3.00A
1.00A - 6.50A
2.00A - 13.50A
-
Resolution
L
0.001A
-
H
0.01A
-
Accuracy
± (1% of reading +5counts)
-
Power
Range
L
0.0W - 60.0W
0.0W - 120.0W
0.0W - 240.0W
-
H
50W - 250W
100W - 500W
200W - 1000W
-
Resolution
L
0.1W
-
H
1W
-
Accuracy
± (2% of reading +5counts)
-
GENERAL
Memory
3 memories (M1, M2, M3)
Efficiency
≧80%(at Full Load )
Protection
Over Power, Over Current, Over Voltage, Over Temperature, Hi- A
Calibration
Front Panel Calibration
Environment
0-40℃/20-80%RH
Dimension (W×H×D) mm
430 x 89 x 300
430 x 89 x 400
430 x 89 x 500
430x 222x 500
Net Weight
12.5Kg
18.2Kg
30Kg
65Kg