| SPECIFICATIONS |
| MODEL |
7470 |
7472 |
7473 |
7474 |
| Output Rating |
10KVAC/20mA |
12KVDC/10mA |
20KVAC/10mA |
20KVDC/5mA |
| DC WITHSTAND VOLTAGE (7472&7474) |
| Output Voltage, DCV (for 7474) |
0 - 20000 |
10 |
±(2% of setting + 20V) |
| Output Voltage, DCV (for 7472) |
0 - 12000 |
10 |
±(2% of setting + 10V) |
| Output Ripple |
<5%(在20KV/5000µA for 7474, 12KV/9999µA at Resistive Load for 7472) |
| SETTINGS |
| Hi / Lo -Limit DC Current, µA (for 7474) |
0.0 - 999.9/1000 - 5000 |
0.1/1 |
±(2% of setting + 2counts) |
| Hi / Lo -Limit DC Current, µA (for 7472) |
0.0 - 999.9/1000 - 9999 |
0.1/1 |
±(2% of setting + 2counts) |
| Ramp Up Time, second |
0.4 - 999.9 |
0.1 |
±(0.1% + 0.05sec) |
| Ramp Down Time, second |
0.0,1.0 - 999.9 |
0.1 |
| Dwell Time |
0, 0.4 - 999.9 sec (0=continuous) |
0.1 |
| 0, 0.1 - 999.9 min (0=continuous) |
0.1 |
| 0, 0.1 - 999.9 hr (0=continuous) |
0.1 |
| Cycle Test |
0 - 9999 Times, (0=continuous) |
| Arc Detection |
Range 1 - 9 (9 is the most sensitivity) |
| DC Current Offset, µA |
0.0 - 200.0 or Auto Set (Option ) |
| Ramp High Current |
ON/OFF, User Selection |
| Charge - Low Current, µA |
0.0 - 350.0 or Auto Set |
| Discharge Time |
< 200 msec |
| Maximum Capacitive Load |
1.5µF < 2KV 0.15µF < 8KV 0.12µF < 14KV 0.08µF < 20KV |
| 0.28µF < 4KV 0.15µF < 10KV 0.1µF < 16KV |
| 0.18µF < 6KV 0.12µF < 12KV 0.08µF < 18KV |
| MEASUREMENT |
| DC Voltage, KV (for 7474) |
0 - 20.00 |
0.01 |
±(1.5% of reading + 2count) |
| DC Voltage, KV (for 7472) |
0 - 10.00 |
0.01 |
±(1.5% of reading + 2count) |
| DC Current Range, µA |
0-350.0 |
0.1 |
± (2% of reading + 3counts) |
| 300-3500 |
1 |
3000 - 5000 (for 7474)
3000-9999 (for 7472) |
10 |
| GENERAL |
| Input Voltage AC |
115/230VAC ± 15% , 50/60Hz ± 5% Fuse: 6.3A Slow |
| PLC Remote Control |
Input : Test , Reset , Memory1.2.3 ,Interlock |
| Output : Pass , Fail , Processing |
| Safety |
Smart-GFI Function (<1mA) |
| Memory |
50 memories |
| Display |
20*2 LCD with back light |
| Key Lock |
To prevent unauthorized alteration of the test Parameters |
| Calibration |
Build-in software and external calibrated meters |
| Interface |
RS232/GPIB /Printer Card (Option) |
| Alarm Volume Setting |
10 ranges set by the numeric keys on the front panel |
| Environment |
0-40℃, 20-80%RH |
| Dimension |
430mm(W)×133mm(H)×400mm(D) |
| Net Weight |
24Kg |
24Kg |
22.5Kg |
23Kg |
| STANDARD ACCESSORIES |
| Power Cord (10A) |
×1 |
| Fuses |
×2 (Including a spare contained in the fuse holder) |
| Interlock Disable Key (1505) |
×1 |
| Hipot Test Lead ,1.5m (1142) |
- |
- |
×1 |
×1 |
| Hipot Test Lead ,1.5m (1143) |
×1 |
×1 |
- |
- |
| Hipot Return Lead ,1.8m (1144) |
×1 |
×1 |
×1 |
×1 |